BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Australian Tunnelling Society - ECPv6.15.20//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://australiantunnellingsociety.com.au
X-WR-CALDESC:Events for Australian Tunnelling Society
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Australia/Melbourne
BEGIN:STANDARD
TZOFFSETFROM:+1100
TZOFFSETTO:+1000
TZNAME:AEST
DTSTART:20250405T160000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+1000
TZOFFSETTO:+1100
TZNAME:AEDT
DTSTART:20251004T160000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+1100
TZOFFSETTO:+1000
TZNAME:AEST
DTSTART:20260404T160000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+1000
TZOFFSETTO:+1100
TZNAME:AEDT
DTSTART:20261003T160000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+1100
TZOFFSETTO:+1000
TZNAME:AEST
DTSTART:20270403T160000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+1000
TZOFFSETTO:+1100
TZNAME:AEDT
DTSTART:20271002T160000
END:DAYLIGHT
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Australia/Melbourne:20260513T173000
DTEND;TZID=Australia/Melbourne:20260513T183000
DTSTAMP:20260415T054959
CREATED:20260330T020114Z
LAST-MODIFIED:20260330T020114Z
UID:269673-1778693400-1778697000@australiantunnellingsociety.com.au
SUMMARY:Choosing the right VSD for tunnel ventilation application
DESCRIPTION:Overview\nIn recent years\, several tunnel projects have faced serious setbacks due to catastrophic motor failures. These failures are caused by high peak voltages\, a result of using Active Front End (AFE) VSDs combined with long motor cable lengths\, extending to 500 meters. This session examines the underlying electrical phenomena contributing to these issues and why conventional mitigation methods\, such as standard filters\, are often insufficient. \nParticipants will gain practical insight into proven engineering solutions that deliver near-sinusoidal voltage at the motor terminals\, reducing stress on insulation and extending asset life. Drawing on real-world case studies and field testing\, the session highlights key design considerations\, specification pitfalls\, and lessons learned to support more reliable tunnel ventilation system performance. \nLearning outcomes\nIn this event\, attendees will be able to: \n\nidentify the root causes of high peak voltages in AFE VSD tunnel applications\nevaluate why conventional filtering methods may not adequately protect motors apply practical design and specification strategies to prevent premature motor failure\nselect VSD and mitigation solutions that improve reliability and extend asset life\n\nProgram\nIn-person: \n\n5.00 pm AEST: Guest arrivals and registrations\n5.30 pm AEST: Presentation begins\n6.15 pm AEST: Q/A begins\n6.30 pm AEST: Event close\n\nOnline: \n\n5.30 pm AEST: Presentation begins\n6.30 pm AEST: Presentation ends\n\nAbout the speakers\n\n\n\nJoris Feekman\nRegional Sales Manager\, Danfoss Drives\n\nJoris is Regional Sales Manager at Danfoss Drives\, with over 25 years of experience in electrical drives and industrial power conversion. He has experience across Europe and Australia\, delivering reliable motor control solutions across a wide range of industrial applications.\n\n\n\n\n\n\n\n\nHusain Natalwala\nBusiness Development Manager\, Danfoss Drives\nHusain has strong experience supporting large-scale industrial and infrastructure projects\, with exposure to Industrial Automation and Electrical Systems. At Danfoss\, he works as a BDM focussing on Tunnel Ventilation\, Water and Food Industries.
URL:https://australiantunnellingsociety.com.au/ats-event/choosing-the-right-vsd-for-tunnel-ventilation-application/
LOCATION:Online and in person at EA Melbourne\, Level 26\, 181 William Street\, Melbourne\, VIC\, 3000\, Australia
CATEGORIES:Online,Victoria,Webinar
ATTACH;FMTTYPE=image/png:https://australiantunnellingsociety.com.au/wp-content/uploads/2026/03/Screenshot-2026-03-30-130022.png
END:VEVENT
END:VCALENDAR